Emerson RTM-ATCA-7150 Power Supply User Manual


 
Hardware Installation of ATCA-7150
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)
72
3.3.2 Power Requirements
Make sure that the blade is used in an AdvancedTCA shelf connected to -48VDC up to -60VDC,
according to Telecommunication Network Voltage (TNV-2). A TNV-2 circuit is a circuit whose
normal operating voltages exceed the limits for a safety-extra-low-voltage (SELV) under
normal operating conditions, and which is not subject to overvoltages from
telecommunication networks.
Table 3-3 lists the power requirements for the ATCA-7150.
The blade provides two independent power inputs according to the AdvancedTCA
specification.
Free Fall 1,200 mm (Packaged) /all
edges and corners
1.0m (Packaged) per ETSI
300 019-2-2 (Blade level
packaging)
25 mm (unpackaged) per
GR-63-CORE
Table 3-2 Environmental Requirements (continued)
Requirement Operating Non-Operating
Table 3-3 Power Requirements
Requirement Operating
Rated Voltage -48VDC to -60VDC
US and Canada: -48VDC
Operating Voltage -39.0VDC to -72VDC
US and Canada: -39.0 to -60VDC
Input Current 3.75A at 48V
Power Dissipation 180W (max) 140W (min)