Ericsson LBI-39076B Network Card User Manual


 
CONFIGURATION LBI-39076
B
31
Line Active - This column of parameters defines (for
the site) if a line is available for interconnect calls.
Default is no (N) for all lines. Enter Y for yes, or leave
N for no. Note that a line number gets its number from
the radio channel number that shares the same GTI
Unit. Also note that GTI Units are placed on the
highest available channel numbers first.
Line Definition (menu selection 14)
Line Parameters (pages 1 & 2)
Pulse Dial - This column of parameters defines (for the
site) if a line uses pulse dialing. Default is no (N) for
all lines. Note that the ELI system will ignore this
parameter, so there is no point in changing it from its
default value. However, the equivalent of this
parameter must be set in the GTI user database. (See
the GTI Configurator Software user’s guide, LBI-
39077.)
Line Definition (menu selection 14)
Line Parameters (pages 1 & 2)
Message Conv Limit - This 4-digit field defines (for
the site) the conversation time limit(in seconds) for
interconnect calls (and message trunking). Default is
300 seconds. Enter a number from 10 to 2550.
Site/Device Definition (menu selection 10)
Site Parameters (panel 2)
Channel Assignment Parameters
Interconnect Hang Time - This 2-digit field defines
(for the site) the time (in seconds) between an unkey
command and channel drop. Default is 30 seconds. Do
not enter a number larger than 60 (see note).
Site/Device Definition (menu selection 10)
Site Parameters (panel 2)
Channel Assignment Parameters
Although the Interconnect Hang Time (IHT) can
be set higher than 60 seconds, the GTI unit will
wait no more than 60 seconds for a telephone-
originated call to be answered. Therefore, setting
the IHT to more than 60 seconds will not allow
more than 60 seconds for the call to be
answered.
NOTE
The voice prompt played to the caller (as the
result of an unanswered telephone-originated
call) will depend upon whether the IHT or the
60-second GTI interval expires first. If the IHT
is set to less than 60 seconds, it will expire first
and the GTI unit will play voice prompt #6.
(Default = Call is disconnecting) If the IHT is
set to more than 60 seconds, the 60-second GTI
interval will expire first and the GTI unit will
play voice prompt #5. (Default = Radio didn’t
answer) If the IHT is set exactly to 60 seconds,
either voice prompt #5 or #6 may be played, due
to slight timing variances.
NOTE
Max # Concurrent Intercon - This 2-digit field
defines (for the site) the maximum number of
simultaneous telephone interconnect calls permitted.
Default is 2.
Site/Device Definition (menu selection 10)
Site Parameters (panel 2)
Channel Assignment Parameters
Who Can Receive Calls
Inb Interconnect - This 1-digit field defines (for each
logical unit ID) if inbound interconnect calls are
allowed for this specific logical unit ID. Default is no
(N). Enter Y for yes, or leave N for no.
Logical Unit Definition (menu selection 11)
Radio Parameters (panel 2)
Radio Features
Inb Interconnect - This 1-digit field defines (for each
group ID) if inbound interconnect calls are allowed for
this specific group ID. Default is no (N). Enter Y for
yes, or leave N for no.
Group Definition (menu selection 12)
Group Parameters (panel 2)
Features