Extreme Networks 200 Series Switch User Manual


 
Setting the System Recovery Level
Summit 200 Series Switch Installation and User Guide 175
Setting the System Recovery Level
You can configure the system to automatically reboot after a software task exception, using the
following command:
config sys-recovery-level [none | critical | all]
where:
The default setting is none.
NOTE
Extreme Networks recommends that you set the system recovery level to critical. This allows
ExtremeWare to log an error to the syslog and automatically reboot the system after a critical exception.
Logging
The switch log tracks all configuration and fault information pertaining to the device. Each entry in the
log contains the following information:
Timestamp—The timestamp records the month and day of the event, along with the time (hours,
minutes, and seconds) in the form HH:MM:SS. If the event was caused by a user, the user name is
also provided.
Fault level—Table 48 describes the three levels of importance that the system can assign to a fault.
[Space] Cycles through the following screens:
Packets per second
Bytes per second
Percentage of bandwidth
Available using the show port utilization command only.
none
Configures the level to recovery without a system reboot.
critical
Configures ExtremeWare to log an error into the syslog and
automatically reboot the system after a critical exception.
all
Configures ExtremeWare to log an error into the syslog and
automatically reboot the system after any exception.
Table 48: Fault Levels Assigned by the Switch
Level Description
Critical A desired switch function is inoperable. The switch may need to be reset.
Warning A noncritical error that may lead to a function failure.
Table 47: Port Monitoring Display Keys (continued)
Key(s) Description