Fujitsu BX600 Server User Manual


 
Device Configuration Commands Command Reference
Intelligent Blade Panel Module
170
7.4.11 Service VLAN
7.4.11.1 Show Commands
This command display the Service VLAN information.
Syntax
show svc-vlan [<svcVlanName>]
<svcVlanName> - The name of Service VLAN which user want to display.
Default Setting
None
Command Mode
Privileged Exec
Display Message
Service VLAN name: This indicates the name of Service VLAN
VLAN ID: The VLAN Identifier of the Service VLAN. The range of the VLAN ID is from 1 to
4094.
Internal Ports: Internal interface, member of that Service VLAN.
Uplink Set Name: Specified the Uplink Set for the external connection.
External Ports: External interface, member of the specified Uplink Set.
7.4.11.2 Configuration Commands
7.4.11.2.1 svc-vlan
This command is used to create or destroy a Service VLAN.
Syntax
svc-vlan <svcVlanName> <1-4094> <uplinkSetName>
no svc-vlan <svcVlanName>
<svcVlanName> - A string associated with Service VLAN as a convenience.
<1-4094> - VLAN ID
<uplinkSetName> - which uplink set to be the external connection for this service VLAN.