Fujitsu BX600 Server User Manual


 
Management Commands Command Reference
Intelligent Blade Panel Module
178
Control is always disabled.
Stop Bits: The number of Stop bits per character. The number of Stop bits is always 1.
Parity: The Parity Method used on the Serial Port. The Parity Method is always None.
Password Threshold: When the logon attempt threshold is reached on the console port, the
system interface becomes silent for a specified amount of time before allowing the next
logon attempt. (Use the silent time command to set this interval.) When this threshold is
reached for Telnet, the Telnet logon interface closes.
Silent Time (sec): Use this command to set the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts exceeds the threshold set by
the password threshold command.
7.5.2.2 line console
This command is used to enter Line configuration mode
Syntax
line console
Default Setting
None
Command Mode
Global Config
7.5.2.3 baudrate
This command specifies the communication rate of the terminal interface. The supported rates
are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.
Syntax
baudrate {1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200}
no baudrate
no - This command sets the communication rate of the terminal interface to 9600.
Default Setting
9600
Command Mode
Line Config