Fujitsu C120-E276-11ENZ0(A) Network Card User Manual


 
Appendix A Messages
This chapter explains messages displayed by the FUJITSU PCI GigabitEthernet driver.
A.1 Console Messages from the Driver
Messages from the FUJITSU PCI GigabitEthernet driver are listed in the following table.
Table A.1 Console Messages(NOTICE) from the FUJITSU PCI GigabitEthernet Driver
No Message Cause Workaround
1 free send descriptor failed ([detail])
Freeing of the descriptor to send
failed.
Please report this error to your service
provider.
2 (Other messages)
There is a possibility of driver
internal bug or hardware
failure.
Report the error to your service provider.
Table A.2 Console Messages(WARNING) from the FUJITSU PCI GigabitEthernet Driver
No Message Cause Workaround
1 soft state alloc failed.
Allocating of the memory
resource failed.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
2
Allocation of descriptor memory failed
The driver could not allocate
internal resources for DMA.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
3
Could not allocate DMA handle
The driver could not allocate
DMA resources.
4 Could not bind descriptor memory
5 Multiple fragments in descriptor area
An error was found in message
fragmentation.
Re-activate the interface. If this message
is still displayed, report to your service
provider.
6
Unable to map adapter registers.
Mapping of the adapter
registers failed.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
7
ddi_get_iblock_cookie-ERROR
The driver could not allocate
interrupt resources.
8 Unable to install interrupt routine.
9 ATTACH failed
The driver was not loaded to the
kernel successfully.
10
Duplex are invalid !! Please change the
partner's duplex Full.
With SE0X7GD2X, the remote
device is using half duplex
mode.
With SE0X7GD2X, only full duplex is
available. Change the duplex mode of the
remote device to Full.
11 Identify failed.
Identification of the interface
information failed.
Check whether the system is supported.
If the system is supported, there is a
possibility of hardware abnormalities.
Please replace the adapter.
12
ddi_intr_block_enable failed
Enabling of the interrupt failed.
Try re-enabling the driver. If this
message is still displayed, report to your
service provider.
13 ddi_intr_enable failed
14 ATTACH failed ([detail]) Loading of the driver failed.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
- 58 -