Fujitsu MX130 S2 Server User Manual


 
MX130 S2 Upgrade and Maintenance Manual 191
Processors
Ê Fasten the four captive screws on the heat sink (screw torque: 0.6 Nm, not
applicable for the Japanese market).
Ê Connect the CPU fan cable to the system board connector FAN1.
11.2.6 Concluding steps
Perform the following procedures to complete the task:
Ê Follow all procedures described in section "Closing the server" on page 54.
11.3 Replacing the processor
V CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.3.1 Required tools
Preliminary and concluding steps: tool-less
Removing and installing the processor heat sink:
Phillips PH2 / (+) No. 2 screw driver
Removing and installing the processor: tool-less
Field Replaceable Units (FRU)
Average hardware task duration: 15 minutes
Average software task duration: 5 minutes