GE 994-0089 Barcode Reader User Manual


 
GE Energy
58
994-0089–1.00–2, General
Ethernet RJ-45 Connector Signal Definitions
Position Function Signal Flow Color
1 RX+ IN White w/ Orange
2 RX- IN Orange
3 TX+ OUT White w/ Green
4 P1+ - Blue
5 P1- - White w/ Blue
6 TX- OUT Green
7 P2+ - White w/ Brown
8 P2- - Brown
Shield - -
Ethernet Crossover Cable (RJ-45) Pin Out
D400 Switch/Hub
Name Pin Pin Name
TX_D1+ 1 3 RX_D2+
TX_D1- 2 6 RX_D2-
RX_D2+ 3 1 TX_D1+
RX_D2- 4 2 TX_D1-
BI_D3+ 5 7 BI_D4+
BI_D3- 6 8 BI_D4-
BI_D4+ 7 4 BI_D3+
BI_D4- 8 5 BI_D3-
Ethernet Straight-Through Cable (RJ-45) Pin Out
D400 PC
Name Pin Pin Name
TX_D1+ 1 1
RX_D2+
TX_D1- 2 2 RX_D2-
RX_D2+ 3 3 TX_D1+
RX_D2- 4 4 TX_D1-
BI_D3+ 5 5 BI_D4+
BI_D3- 6 6 BI_D4-
BI_D4+ 7 7 BI_D3+
BI_D4- 8 8 BI_D3-