GE 994-0089 Barcode Reader User Manual


 
GE Energy
78
994-0089–1.00–2, General
The default IP address is 192.168.168.81.
6. Enter the Subnet Mask of the D400.
The default Subnet Mask is 255.255.255.0.
7. Enter the DNS Server address. If the DNS Server address is not required, press Enter
to continue.
8. Enter the Gateway IP address. If the Gateway IP address is not required, press Enter
to continue.
A summary of the configured settings displays.
9. Do one of the following:
To accept the settings, enter Y.
To change the settings, enter N and repeat Steps 2 to 8 to make the necessary
changes.
10. When you return to the D400 Configuration Utility Menu, select 8. Quit to exit the
configuration utility and return to the D400 prompt.
11. At the D400#>> prompt, type reboot and press Enter.
The D400 restarts and is updated with the new network settings.
Refer to the D400 online help and D400 Software Configuration Guide for information on
configuring the D400 software.