GFK-2251 Chapter 1 Panel C Industrial Computer Features 1-3
1
Removable Hard Disk Drive
The Hard Disk Drive can be quickly removed for servicing or substitution.
Warning
Before installing or removing the Hard Disk Drive, remove power
from the unit. The proper method for removing power from the unit
is to switch off power at the circuit breaker.
CD-ROM
The external CD-ROM connector is located on the side access panel.
Warning
Before installing or removing the CD-ROM, remove power from the
unit. The proper method for removing power from the unit is to
switch off power at the circuit breaker.
Front Panel Keypads
The front panel is supplied with 26 function keys that double as a full alpha keypad. You
can enter all 26 alpha characters, selecting lower or upper case via the Fn and CAPS
LOCK keypads. A full numeric keypad with 13 additional alpha characters is available with
the SHIFT keypad. There are 12 control keys and 4 arrow keys. There are 16 special
function keypads for use in application software.
Status LEDs
Front panel mounted LEDs indicate Power, Hard Disk Drive (HDD) status, Compact Flash
inserted, and System error status. An LED will also indicate when the Fn keypad is
selected. The floppy drive has its own status indicator.