Gefen EXT-DVI-16416 Switch User Manual


 
15
RS-232 SERIAL CONTROL COMMANDS
RS-232 Features
RS-232 remote functions are used to control of this product’s features. Features
include input to output routing, EDID storage, EDID management, etc.
Functions Syntax
The syntax for each function is always the same:
#Character as the start ag Function name Space ( _ ) as function name
end ag Parameter 1 Space Parameter n Carriage Return ( \r )
Sample:
#FunctionName_param1_param2_param3_param4...\r
Syntax is NOT case sensitive.
Commands
Simpli ed syntax was used for command implementation for faster operation with
the device: # character – isn’t needed, the command name is reduced to 1 letter.
The commands are not case-sensitive.
Command Description
R Routing command
S Routes a single input to all outputs
M Returns the current routing status of matrix
F Toggle 5V ber optic extender feature
R Command
The R command allows speci c routing of inputs and outputs.
Syntax:
r param1 param2
Parameters:
param1 DVI Ouput [1 - 16]
param2 DVI Input [1 - 16]