Gefen EXT-DVI-16416 Switch User Manual


 
32
IP CONTROL - MANAGE EDID
COPY EDID
Pressing the “COPY EDID” button will display additional options. The following
page will open.
On this page, the user can select an EDID from either the LOCAL memory
locations (Input) or from a display that is currently attached to any output, and
copy that EDID to any other LOCAL memory location. This will allow the user to
manage what EDID information will be passed to each source connected to the
16x16 DVI Matrix.
To copy an EDID follow the steps below.
1. Select an EDID from the section ”Select Source to Copy from”. The user can
choose an EDID from a display connected to one of the outputs or from an
EDID already loaded into one of the LOCAL memory locations (Input).
NOTE: Please note that only one EDID can be selected for copying.
2. Select the LOCAL memory locations that will receive the selected EDID in
the section “Select Input(s) to Copy to”.
NOTE: Multiple LOCAL memory locations can be speci ed during this step.
3. Click on the “Set EDID” button to initiate the change(s).
NOTE: After this command is complete the user will be returned to the Main
Page.
This page will automatically refresh every minute, however, at anytime the
“Refresh” button can be pressed to refresh the status of the matrix.