Gefen EXT-DVI-16416 Switch User Manual


 
16
RS-232 SERIAL CONTROL COMMANDS
S Command
The S command routes a single input to all 16 DVI outputs.
Syntax:
s param1
Parameters:
param1 Input [0 - 16]
Notes:
Setting param1 to a value of 0 will place the matrix in one-to-one mode. This
means that Input1 will be routed to Output1, Input2 will be routed to Output2, and
so on.
M Command
The M command displays the current routing status of the matrix.
Syntax:
m
Parameters:
None