Gefen EXT-DVI-16416 Switch User Manual


 
22
RS-232 SERIAL CONTROL COMMANDS
#PREDIDST Function
The #PREDIDST function prints a table that contains details relating to the Local
EDID source and the display name.
Syntax:
#PREDIDST
Parameters:
None
#LOCKEDID Function
The #LOCKEDID function secures the Local EDID and disables the automatic
loading after power-up.
Syntax:
#LOCKEDID param1
Parameters:
param1 EDID lock state [0 - 1]
Value Meaning
0 Disable
1 Enable