Honeywell 1280i Scanner User Manual


 
6 - 43
EAN/JAN-8 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda. Default = Not Required.
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned
Off, there is no space. Default = Off.
Addenda Timeout
You can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period,
the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended
Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning
the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart,
then scanning Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
* 5 Digit Addenda Off
Required
* Not Required
On
* Off
Addenda Timeout