Honeywell 1280i Scanner User Manual


 
2 - 1
2
Programming the Interface
Introduction
This chapter describes how to program your system for the desired interface.
Programming the Interface - Plug and Play
Plug and Play bar codes provide instant scanner set up for commonly used interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
RS232 Serial Port
The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface
bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below. It also
changes the trigger mode to manual.
OPOS Mode
The following bar code configures your engine for OPOS (OLE for Retail Point of Sale) by modifying the following OPOS-
related settings:
Option Setting
Baud Rate 9600 bps
Data Format 8 data bits, no parity bit, 1 stop bit
Option Setting
Interface RS232
Baud Rate 38400
RS232 Handshaking Flow Control, No Timeout
XON/XOFF Off
ACK/NAK Off
Data Bits, Stop Bits, and Parity 8 Data, 1 Stop, Parity None
Prefix/Suffix
Clear All Prefixes and Suffixes
Add Code ID and AIM ID Prefix
Add CR Suffix
Intercharacter Delay Off
Symbologies Enable UPC-A with check digit and number system
Enable UPC-E0 with check digit
Enable EAN/JAN-8 with check digit
Enable EAN/JAN-13 with check digit
Enable Code 128
Enable Code 39
Enable OPOS with automatic disable off
RS232 Interface
OPOS Mode