Presentation Mode
When the scanner is in Presentation Mode, it automatically detects bar codes, then scans and transmits the data. To set
the time period before the scanner can read the same bar code a second time use Reread Delay (page 3-11). To return to
trigger scanning, scan the Out-of-Stand Defaults bar code, above.
Manual Activation Mode
In Manual Activation Mode, you must press the trigger to scan a bar code. The scanner scans until a bar code is read, or
until the trigger is released. Default = Manual Activation On Out-of-Stand.
End Manual Activation After Good Read
After a bar code is successfully read, the laser can be programmed either to remain on and scanning, or to turn off. When
End Manual Activation After Good Read is enabled, the laser turns off and stops scanning after a good read. If you scan
Do Not End Manual Activation After Good Read, the laser remains on after a good read, but the trigger must be pressed
to scan the next bar code. Default = End Manual Activation After Good Read Out-of-Stand.
Presentation Mode Out-
of-Stand
Manual Activation Mode Off
Out-of-Stand
* Manual Activation Mode On
Out-of-Stand
Do Not End Manual Activation
After Good Read Out-of-Stand
* End Manual Activation After
Good Read Out-of-Stand