Honeywell 1280i Scanner User Manual


 
6 - 25
Telepen Redundancy
If you are encountering errors when reading Telepen bar codes, you may want to adjust the redundancy count. Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan
the Telepen Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart
inside the back cover of this manual. Then scan the Save bar code. Default = 0.
Telepen Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional
information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.
UPC-A
<Default All UPC-A Settings>
UPC-A On/Off
Note: To convert UPC-A bar codes to EAN-13, see Convert UPC-A to EAN-13 on page 6-34.
Telepen Redundancy
Minimum Message Length
Maximum Message Length
* On
Off