Hyundai HX300 Robotics User Manual


 
HX200/HX200L-2000/HX300/HX300L/HX400
3-10
3.4.4. Accuracy of Installation Surface
The degree of flatness for the four attachment plate surfaces should safisty the
specification. Use a shim, if necessary. The rest of the surface must be flat within
±2mm.
■ Cautions
(1) The flatness of mounting plate must be within 1.0 mm.
(2) The flatness of attachment plate surface for the 4 points must be within 1.0
mm (±0.5 mm).
Fig 3.7 Accuracy of Installation surface