IBM M71V2 Network Card User Manual


 
84
Unchecked* Disable the sending of leading or trailing start characters with the
bar code.
Check Char
NONE* Do not validate the check characters and do not send any check
characters with the bar code.
TEST Validate the check character but do not send it with the bar code.
Bar code must be printed with a check character.
SEND Validate and send the check character with the bar code. Bar code
must be printed with a check character.
Length Min
Default = 0 The minimum number of characters in the scanned bar code.
Length Max
Default = 48 The maximum number of characters in the scanned bar code.
Append
Checked Allows multiple bar codes to be scanned before the bar code data is
sent to the system. Every bar code that starts with a space will be
stored until a bar code without a preceding space is scanned.
Unchecked* Disable multiple bar code scanning feature.
Full ASCII
Checked Allows Code 39 bar codes to contain the full ASCII character set.
Unchecked* Disable the full ASCII character set.
Page
Defines the mapping of foreign characters to be inserted into the character codes.
ISO2022* Automatic National Replacement Characters .
CP Bin Swedish Fren 69 Fren 25
German Italian Swiss UK
Danish Norweg. Spanish ISO646 (US)
Setting the PDF417 Bar Code