IBM SH19-4480-01 Laptop User Manual


 
EQQE097E EQQE101E
EQQE097E THE FOLLOWING USER DEFINED EVENT RECORD CANNOT BE USED BECAUSE THE SPECIFIED
TOKEN VALUE DOES NOT MATCH ANY OPERATION IN THE CURRENT PLAN:
EXITREC
Explanation: An invalid user-defined event record has been found on the Event Manager's work queue. An
OPSTAT event definition statement defined a TOKEN value that does not match any operation in the current plan.
The operation cannot be identified by OPC/ESA.
System action: The incorrect event record is returned to the Event Manager's free queue without any further
processing.
User response: If a new event should be created, make the necessary corrections and reissue the command or
resubmit the EQQEVPGM batch job.
EQQE098E THE FOLLOWING USER DEFINED EVENT RECORD CANNOT BE USED BECAUSE THE CURRENT
OPERATION STATUS IS SS:
EXITREC
Explanation: An invalid user-defined event record has been found on the Event Manager's work queue. An
OPSTAT event definition statement specifies a new status Q for an operation which has a current status SS. This is
not allowed
System action: The incorrect event record is returned to the Event Manager's free queue without any further
processing. The workstation status is not changed.
User response: If a new event should be created, make the necessary corrections and reissue the command or
resubmit the EQQEVPGM batch job.
EQQE099E THE FOLLOWING USER DEFINED EVENT RECORD CANNOT BE USED BECAUSE THE
ALTERNATE WORKSTATION
WSNAME
DOES NOT EXIST:
EXITREC
Explanation: An invalid user-defined event record has been found on the Event Manager's work queue. A WSSTAT
event definition statement specified an alternate workstation that did not exist.
System action: The incorrect event record is returned to the Event Manager's free queue without any further
processing. The workstation status is not changed.
User response: If a new event should be created, make the necessary corrections and reissue the command or
resubmit the EQQEVPGM batch job.
EQQE100E THE CURRENT WORKSTATION
WSNAME
CANNOT BE USED AS ALTERNATE TO ITSELF.
REROUTE IS NOT IN EFFECT FOR THE WORKSTATION
Explanation: A WSSTAT event definition statement specified an alternate workstation which was the same as the
current workstation.
System action: Reroute will not be in effect for the actual workstation. The workstation status is changed.
User response: None.
EQQE101E KEYWORD
KEY
HAS AN INVALID VALUE
Explanation: The only valid values for the QUANTITY and DEVIATION keywords are KEEP, RESET or a numeric
value.
System action: The event will not be created. Processing ends for current SRSTAT command. If SRSTAT is
invoked by the EQQEVPGM program then processing continues with the next event creation statement.
User response: If the event should be created, make the necessary corrections and reissue the SRSTAT command.
Chapter 8. EQQEnnn Messages 99