IBM SH19-4480-01 Laptop User Manual


 
EQQZ148E EQQZ161E
EQQZ148E HOUR MUST BE IN THE RANGE 0 TO 23
Explanation: A time value has been specified where the hour number is not valid.
System action: Processing continues.
System programmer response: Reenter the time value and specify an hour number in the range 0 through 23.
EQQZ149E MINUTE MUST BE IN THE RANGE 0 TO 59
Explanation: A time value has been specified where the minute number is not valid.
System action: Processing continues.
System programmer response: Reenter the time value and specify a minute number in the range 0 through 59.
EQQZ153E TOO MANY USER DESTINATIONS DEFINED
Explanation: You defined more than 64 destinations in the USER keyword in the ROUTOPTS initialization
statement. At most 64 user defined destinations can be used at the same time.
System action: TME 10 OPC initialization fails and the subsystem terminates.
TME 10 OPC administrator response: Change the USER keyword to specify fewer destinations, then restart the
subsystem.
EQQZ154E THE PIFHD KEYWORD IS MISSING OR INVALID
Explanation: The PIFHD keyword on the INTFOPTS initialization statement is required. You have not defined the
keyword, or the keyword has an invalid value.
System action: TME 10 OPC initialization fails and the subsystem terminates.
TME 10 OPC administrator response: Change or add the keyword to the INTFOPTS initialization statement and
restart the subsystem.
EQQZ160E LIBRARY WITH DDNAME EQQJCLIB COULD NOT BE OPENED
Explanation: TME 10 OPC could not open a required input data set, ddname EQQJCLIB. This message can be
issued:
During initialization of the Event Writer task.
When processing a modify command with the NEWDSLST option.
System action: If the message was issued when processing a modify command, the previously built dataset
selection table remains in effect. If the error occurs during initialization, dataset triggering functions are not available.
System programmer response: If the dataset triggering function should be active, check that EQQJCLIB is correctly
defined and that TME 10 OPC started task is authorized to open the data set. Restart the tracker or issue the modify
command when the problem has been corrected.
EQQZ161E UNABLE TO ALLOCATE STORAGE TO PROCESS MEMBER EQQDSLST OF EQQJCLIB
Explanation: An error occurred when allocating storage to build a dataset selection table. This message can be
issued:
During initialization of the Event Writer task.
When processing a modify command with the NEWDSLST option.
System action: If the message was issued when processing a modify command, the previously built dataset
selection table remains in effect. If the error occurs during initialization, dataset triggering functions are not available.
System programmer response: Verify that the EQQDSLST member in the EQQJCLIB library is not unexpectedly
large. If not, determine which product/program is exhausting ECSA storage. Restart the tracker or issue the modify
command when the problem has been corrected.
426 TME 10 OPC Messages and Codes