IBM SH19-4480-01 Laptop User Manual


 
EQQL568I EQQL706E
EQQL568I
LTPCHDD
,
LTPCHDT
DEADLINE PAST OCCURRENCE TIME LIMIT
Explanation: The operation deadline
LTPCHDD, LTPCHDT
is outside the occurrence time limit.
System action: None.
User response: None.
EQQL570I THE INPUT ARRIVAL SPECIFIED IS LATER THAN THE DEADLINE
Explanation: The operation input arrival date and time are later than the application deadline.
System action: The system waits for you to respond.
User response: Change the input arrival date and time if they are not what you intended.
EQQL572E DATE OR TIME IS MISSING FROM THE INPUT ARRIVAL
Explanation: Data entry error; see “Data Entry Errors” on page 2.
EQQL573E DATE OR TIME IS MISSING FROM THE DEADLINE
Explanation: Data entry error; see “Data Entry Errors” on page 2.
EQQL701E INVALID DATA LENGTH IN LONG TERM PLAN REQUEST:
L
Explanation: An internal parameter list, consisting of a sequence of control blocks followed by an application
description record, was validated and found to have an invalid length.
System action: If this is a request to the program interface function, the request is rejected and control is returned
with the return code set to error.
Problem determination: The diagnostic file of the TME 10 OPC subsystem (ddname EQQDUMP) contains a dump
of the control blocks.
User response: This is likely to be an internal error. If possible, do the requests in a different order and rerun.
System programmer response: If you cannot find a valid reason for the error, make the diagnostic file and the
message log available and contact your IBM representative.
EQQL705E THE APPLICATION DESCRIPTION
AD
COULD NOT BE FOUND REQUESTED AS PREDECESSOR
TO LTP OCCURRENCE
LTOC
Explanation: The application
AD
is specified in a program interface request to set up a dependency between two
long-term plan occurrences. Its application description could not be found.
System action: If this is a request to the program interface function, the request is rejected and control is returned
with the return code set to error.
User response: Correct the application ID and resubmit the job.
EQQL706E PREDECESSOR OPERATION
WSN
OPNO
DOES NOT EXIST IN AD
AD
REQUESTED AS
PREDECESSOR TO LTP OCCURRENCE
LTOC
Explanation: The operation
WSN
OPNO
is specified in a program interface request to set up a dependency between
two long-term plan occurrences. The specified application description does not contain the operation.
System action: If this is a request to the program interface function, the request is rejected and control is returned
with the return code set to error.
User response: Correct the application ID, workstation name, or operation number and resubmit the job.
Chapter 15. EQQLnnn Messages 169