IBM SH19-4480-01 Laptop User Manual


 
EQQY302E EQQY702E
EQQY302E LOGICAL RECORD SIZE OF OI MEMBER DATA SET, DDNAME EQQOIPDS, IS NOT VALID
Explanation: The EQQOIPDS dataset must have a logical record length of 80.
System action: No operator instructions are created for OISTART statements with the MEMBER keyword specified.
User response: Convert the EQQOIPDS dataset to record length 80 and resubmit the job.
EQQY303E MEMBER
MEM
DOES NOT EXIST IN THE EQQOIPDS DATA SET
Explanation: The batch loader statement OISTART specifies a PDS member name which does not exist in the
dataset allocated to ddname EQQOIPDS.
System action: Processing continues. The creation of the current record is abandoned, and the remaining
statements for the same record are bypassed.
User response: Correct the member name or check that the correct dataset is allocated to the EQQOIPDS ddname.
EQQY304E ERROR OCCURRED WHILE READING MEMBER
MEM
FROM THE EQQOIPDS DATA SET
Explanation: The PDS member could not be read.
System action: Processing continues. The creation of the current record is abandoned, and the remaining
statements for the same record are bypassed.
Problem determination: The preceding message gives detailed information about the read error.
User response: Follow the instructions for the preceding message.
EQQY306W TOO LONG OI ROW ENTERED, STARTS BY
ST
. IT IS TRUNCATED
Explanation: You entered an OI text row longer than 72 characters. It is truncated to 72 characters.
System action: The OI is created.
User response: Correct the input file and resubmit the job.
EQQY700E THE COMMUNICATION BLOCK PARAMETER DOES NOT POINT TO A COMMUNICATION BLOCK
Explanation: The validation of the parameters in a program interface call found that the communication block
address is not locating a valid communication block.
System action: Processing continues.
User response: Ensure that the communication block address returned at the INIT request is used in the following
program interface requests. Also ensure that the area located by the communication block address is not overlayed
and that there was no error at the INIT request.
EQQY701E INVALID PARAMETER VALUE IN CALL TO EQQYCOM, PARAMETER:
PAR
, VALUE:
REQ
Explanation: The
PAR
parameter (could either be REQUEST or RESOURCE) has an unsupported value
REQ
.
System action: The request is rejected.
User response: Correct the request and resubmit the job.
EQQY702E UNSUPPORTED ARGUMENT NAME:
ARG
IN
REQ
STATEMENT, RESOURCE IS
RES
Explanation: The
ARG
argument is not supported for the specified request type and resource.
System action: The request is rejected.
User response: Correct the request and resubmit the job.