EQQW763E EQQW766W
EQQW763E AN ABEND OCCURRED WHEN THE SUBMITTOR TASK WAS STOWING THE MEMBER FOR STC
STCNAME
ON THE EQQSTC DATA SET. THE ABEND CODE WAS:
ABCODE
Explanation: The submittor task got an ABEND when stowing on EQQSTC, the started task temporary proclib file.
An ABEND exit routine was given control and issued an ABEND code.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
The corresponding operation is set to status E.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: See
MVS/ESA Message Library: System Codes
for an explanation of the ABEND
code, and take appropriate action.
EQQW764E THE SUBMITTOR TASK GOT AN UNEXPECTED RETURN CODE WHEN STOWING THE MEMBER
NAME FOR STC
STCNAME
ON THE EQQSTC DATA SET THE RETURN AND REASON CODE WAS
RC
Explanation: The submittor task got an unexpected return code when stowing a member on EQQSTC, the started
task temporary proclib file.
The return code is the content of register 15, and the reason code is the content of register 0 after the STOW macro.
The corresponding operation is set to status E.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: Use the return code and reason code to determine the cause of the error. For
more information, refer to the documentation about the STOW macro for the currently active MVS/ESA system.
EQQW765E THE SUBMITTOR TASK GOT AN UNEXPECTED RETURN CODE WHEN ISSUING THE MGCR
MACRO FOR STC
STCNAME
Explanation: The submittor task got an unexpected return code when the MGCR macro was invoked to start an
STC.
The corresponding operation is set to status E.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
System programmer response: Use the return code and reason code to determine the cause of the error. For
more information, refer to the documentation about the MGCR macro for the currently active MVS/ESA system.
EQQW766W THE EVENT CREATION ROUTINE DETECTED THAT THE JES2 EXIT7 (EQQEXIT) IS ON A LOWER
RDMID LEVEL THAN THE OPC/ESA SUBSYSTEM MODULE EQQZEV2X
Explanation: The level of the EQQEXIT macro in JES2 EXIT7 (OPCAXIT7) is at a lower maintenance level than the
TME 10 OPC subsystem.
System action: The event creation routine continues to create event records. The event records may contain invalid
tracking information, causing the corresponding operation status to be inaccurate.
Operator response: If necessary, set the correct operation status manually.
System programmer response: Apply the EXIT7 again, and make sure that the appropriate maclibs are used in the
SYSLIB concatenation. If you are assembling the OPCAXIT7 outside the JES2 SMP environment, make sure that you
have the SMPMTS dataset concatenated first in the SYSLIB concatenation.