IBM SH19-4480-01 Laptop User Manual


 
EQQX100E EQQX114E
EQQX100E ONLY ONE ROW COMMAND CAN BE SPECIFIED ON THIS PANEL
Explanation: It is not allowed to specify more than one row command on this panel.
System action: The system waits for you to respond.
User response: Enter the RESET command to remove all row commands, and then enter one row command.
EQQX101I PENDING APPLICATION DESCRIPTION DOES NOT GIVE OCCURRENCES
Explanation: The Modify LTP One program, which is generated with the L command, will delete any entry of the
pending version of the application and will add any active versions of it. Also, being a Modify LTP One, dependencies
will not be resolved.
System action: Processing continues.
User response: Decide whether to submit the job.
EQQX110E
XOPCNM
IS NOT A VALID SUBSYSTEM NAME
Explanation: Data entry error; see “Data Entry Errors” on page 2.
You can change the name to a valid subsystem name if you go to the TME 10 OPC main menu and select 0,
OPTIONS.
EQQX111E
XOPCNM
IS NOT AN ACTIVE OPC/ESA SUBSYSTEM
Explanation: The subsystem (
XOPCNM
) you selected is not active.
System action: The system waits for you to respond.
User response: Change the subsystem name to a valid name by going to the TME 10 OPC main menu and
selecting 0, OPTIONS. If the name is a valid subsystem name, ask your system programmer to start the subsystem.
System programmer response: Start the subsystem.
EQQX112E NOT ENOUGH STORAGE AVAILABLE
Explanation: A GETMAIN failed at logon to TME 10 OPC because there is not enough storage available.
System action: The system waits for you to respond.
User response: Logon again to TSO with a larger region size.
EQQX113E INCORRECT PARAMETERS TO THE LOGON ROUTINE
Explanation: The logon failed because of incorrect parameters in the input to the logon routine.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Ensure that the correct load module library is accessed and that the dataset
contains the correct version of the TME 10 OPC modules. If the error persists, collect information in the form of the
sequence of actions leading to the error, and if possible, the data it may be dependent on. Then contact your IBM
representative.
EQQX114E OPC/ESA SERVICES REQUIRE TSO/E R2
Explanation: It is not possible to run TME 10 OPC because the prerequisite TSO/E Release 2 system programs are
not installed.
System action: The system waits for you to respond.
User response: Contact your system programmer.
System programmer response: Make sure that TSO/E Release 2 is installed before anyone is allowed to use the
TME 10 OPC dialogs.
Chapter 31. EQQXnnn Messages 331