Detachable AC power cords, each 2.5 m (approximately 8 ft) long, are supplied with
the Services Router. The appliance coupler at the female end of the cord inserts into
the appliance inlet on the faceplate of the AC power supply. The coupler is type C19
as described by International Electrotechnical Commission (IEC) standard 60320.
The plug at the male end of the power cord fits into the power source receptacle that
is standard for your geographical location.
NOTE: In North America, AC power cords must not exceed 4.5 m (approximately
14.75 ft) in. length, to comply with National Electrical Code (NEC) Sections 400-8
(NFPA 75, 5-2.2) and 210-52, and Canadian Electrical Code (CEC) Section 4-010(3).
The cords supplied with the router are in compliance.
Table 56 on page 110 lists AC power cord specifications provided for each country or
region.
Table 56: AC Power Cord Specifications
Plug StandardsElectrical SpecificationsCountry
AS/NZ 3112–1993250 VAC, 10 A, 50 HzAustralia
GB2099.1 1996 and GB1002 1996 (CH1-10P)250 VAC, 10 A, 50 HzChina
CEE (7) VII250 VAC, 10 A, 50 HzEurope (except Italy and
United Kingdom)
CEI 23–16/VII250 VAC, 10 A, 50 HzItaly
JIS 8303125 VAC, 12 A, 50 Hz or 60 HzJapan
NEMA 5-15125 VAC, 10 A, 60 HzNorth America
BS 1363A250 VAC, 10 A, 50 HzUnited Kingdom
Figure 54 on page 110 illustrates the plug on the power cord for each country or region
listed in Table 56 on page 110.
Figure 54: AC Plug Types
NOTE: Power cords and cables must not block access to router components or drape
where people might trip on them.
110 ■ Power Guidelines, Requirements, and Specifications
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide