Chapter 10: Setup Mode: Advanced Settings
XPress DR+ User Guide 90
Disable SNMP
This setting allows you to disable the SNMP protocol on the unit for security reasons.
Disable SNMP (N) ? _
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters.
SNMP Community Name (public): _
The default entry is public. The current value is displayed in parentheses.
Disable Telnet Setup
Note: If you choose to disable this option, keep in mind that disabling both
Telnet Setup and Port 77FE will prevent users from accessing Setup Mode from
the network.
This setting defaults to the N (No) option. The Y (Yes) option disables access to Setup
Mode by Telnet (port 9999). It only allows access locally using the web pages and the
serial port of the unit.
Disable Telnet Setup (N) ? _
Disable TFTP Firmware Upgrade
This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to
perform network firmware upgrades. With this option, you can download firmware
upgrades over the serial port using DeviceInstaller’s Recover Firmware procedure. (See
Chapter 11: Firmware Upgrades and the DeviceInstaller online Help.
Disable TFTP Firmware Update (N) : _
Disable Port 77FE (Hex)
Note: If you choose to disable this option, keep in mind that disabling both
Telnet Setup and Port 77FE will prevent users from accessing Setup Mode from
the network.
Port 77FE is a setting that allows DeviceInstaller, Web Manager, and custom programs to
configure the unit remotely. You may wish to disable this capability for security purposes.
Disable Port 77FEh (N) ? _
The default setting is the N (No) option, which enables remote configuration. You can
configure the unit by using DeviceInstaller, Web Manager, Telnet, or serial configuration.
The Y (Yes) option disables remote configuration and web sites.