Lenovo 6434 Personal Computer User Manual


 
Table 11. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
178x Fixed disk error.
Note: x is the drive that has the error.
1. Run the hard disk drive diagnostic tests
on drive x (see “Running the diagnostic
programs” in the Hardware Maintenance
Manual ).
2. Reseat the following components,
depending on the server model:
v Hot-swap models: Hard disk drive
v Simple-swap models:
a. Hard disk drive x
b. Hard disk drive x cable
3.
Replace the following components one at
a time, depending on the server model,
in the order shown, restarting the server
each time:
v Hot-swap models:
a. Hard disk drive x
b. Hard disk drive backplane
v
Simple-swap models:
a. Hard disk drive x
b. Hard disk drive x cable
4.
(Trained service technician only) Replace
the system board.
1800 Unavailable PCI hardware interrupt.
1. Run the Configuration/Setup Utility
program and adjust the adapter settings.
2. Remove each adapter one at a time,
restarting the server each time, until the
failing adapter is isolated.
Chapter 5. Solving problems 57