Lexmark TN3270E Network Card User Manual


 
126Operations - TN3270E SETUP: MISC SETTINGS > IBM Trn Code (IDB Option 169 bit 1)
IBM Trn Code
(IDB Option 169
bit 1)
This SCS Options > MISC Settings option defines how transparent
data is translated.
Advanced IDB language to set factory default:
&%IDB_EDIT: OPTION 169:0:EXIT
Option Value IDB bit option value Comments
Normal * 0 Transparent data is translated
from EBCDIC to ASCII. Data
outside the range 40H - FEH is
printed as a hyphen. See the
Non-Print Char (IDB Option 3)
option.
No Translation 1 Data within a transparent data
stream (LU-1 (SCS) control
code 35H) is printed as
received. No translation from
EBCDIC to ASCII is
performed. All transparent data
is printed, even invalid data, ie
data in the range 40H - FEH.