MicroNet Technology SP1659P Switch User Manual


 
SP1659P(time)# set ntp 210.59.157.10 8
SP1659P(time)#
show
Syntax: show
Description:
To show the time configuration, including “Current Time”, “NTP Server”,” Timezone”,
” Daylight Saving”,” Daylight Saving Start” and “Daylight Saving End”
Argument: None
Possible value: None
Example:
SP1659P(time)# show
Current Time : Thu Thu 14 15:04:03 2005
NTP Server : 209.81.9.7
Timezone : GMT+8:00
Day light Saving : 0 Hours
Day light Saving Start : Mth: 1 Day: 1 Hour: 0
Day light Saving End : Mth: 1 Day: 1 Hour: 0
SP1659P(time)#
4.3.27 trunk
del trunk
Syntax: del trunk <port-range>
Description: To delete the trunk port.
Argument: <port-range>: port range, syntax 1,5-7, available from 1 to 24
Possible value: <port-range>: 1 to 24
Example:
SP1659P(trunk)# del trunk 1
SP1659P(trunk)#
set priority
Syntax: set priority <range>
Description: To set up the LACP system priority.
Argument: <range>: available from 1 to 65535.
Possible value: <range>: 1 to 65535, default: 32768
Example:
SP1659P(trunk)# set priority 33333
SP1659P(trunk)#
set hash
Syntax: set hash <method>
Description: To set up trunk hash method.
Argument:
<method>: lacp hash method
0: DA and SA
1: SA
2: DA
Possible value: <method>: 0~2
Example:
113