MicroNet Technology SP1659P Switch User Manual


 
Syntax: show parameter
Description: To display the parameter settings of each port.
Argument: None
Possible value: None
Example:
SP1659P(802.1x)# show parameter
port 1) port control : Auto
reAuthMax : 2
txPeriod : 30
Quiet Period : 60
reAuthEnabled : ON
reAuthPeriod : 3600
max. Request : 2
suppTimeout : 30
serverTimeout : 30
port 2) port control : Auto
reAuthMax : 2
txPeriod : 30
Quiet Period : 60
reAuthEnabled : ON
reAuthPeriod : 3600
max. Request : 2
suppTimeout : 30
serverTimeout : 30
:
:
:
show security
Syntax: show security
Description: To display the authentication status of each port.
Argument: None
Possible value: None
Example:
SP1659P(802.1x)# show security
Port Mode Status
====== ============ ==============
1 Disable
2 Multi-host Unauthorized
3 Disable
4 Disable
5 Disable
6 Disable
:
:
show state
Syntax: show state
Description: Show the Radius server configuration
Argument: None
Possible value: None
Example:
SP1659P(802.1x)# show state
Radius Server: 192.168.1.115
Port Number : 1812
Secret Key : WinRadius
73