Choose whether regular authentication will take place in this port.
Default: ON
y reAuthPeriod(1-65535 s):
A non-zero number seconds between the periodic re-authentication of the supplicant.
Default: 3600
y max. Request(1-10):
The maximum of number times that the authenticator will retransmit an EAP Request to the supplicant
before it times out the authentication session. The valid range: 1 – 10.
Default: 2 times
y suppTimeout(1-65535 s):
A timeout condition in the exchange between the authenticator and the supplicant. The valid range:
1 –65535.
Default: 30 seconds.
y serverTimeout(1-65535 s):
A timeout condition in the exchange between the authenticator and the authentication server. The valid
range: 1 –65535.
Default: 30 seconds
3.15 Alarm
3.15.1 Event
The Trap Events Configuration function is used to enable the switch to send out the trap information while
pre-defined trap events occurred. The switch offers 24 different trap events to users for switch management.
The trap information can be sent out in three ways, including email, mobile phone SMS (short message
system) and trap. The message will be sent while users tick (;) the trap event individually on the web page
shown as below.
50