PT-7728 User’s Manual Featured Functions
3-56
Configuring Email Warning
The Auto Email Warning function uses e-mail to alert the user when certain user-configured
events take place.
Three basic steps are required to set up the Auto Warning function:
1. Configuring Email Event Types
Select the desired Event types from the Console or Web Browser Event type page (a
description of each event type is given later in the Email Alarm Events setting subsection).
2. Configuring Email Settings
To configure PT-7728’s email setup from the serial, Telnet, or web console, enter your Mail
Server IP/Name (IP address or name), Account Name, Account Password, Retype New
Password, and the email address to which warning messages will be sent.
3. Activate your settings and if necessary, test the email
After configuring and activating your PT-7728’s Event Types and Email Setup, you can use
the Test Email function to see if your e-mail addresses and mail server address have been
properly configured.
Event Type
Event Types can be divided into two basic groups: System Events and Port Events. System
Events are related to the overall function of the switch, whereas Port Events are related to the
activity of a specific port.
System Events Warning e-mail is sent when…
Switch Cold Start Power is cut off and then reconnected.
Switch Warm Start PT-7728 is rebooted, such as when network
parameters are changed (IP address, subnet mask,
etc.).
Power Transition (OnÆOff) PT-7728 is powered down.
Power Transition (OffÆOn) PT-7728 is powered up.
Configuration Change Activated Any configuration item has been changed.
Authentication Failure An incorrect password is entered.
Comm. Redundancy Topology
Changed
If any Spanning Tree Protocol switches have changed
their position (applies only to the root of the tree).
If the Master of the Turbo Ring has changed or the
backup path is activated.