MRV Communications TS5000/4U1/V*) Mouse User Manual


 
MRV Communications, Inc. – Installation Manual
34
Interfaces
Check the specifications compatibility (type, data rate) between the TereScope and
the peripheral equipment interfaces.
Testing equipment
Chose an appropriate BER (Bit Error Rate) tester for checking the physical link
quality. A portable one is preferred for convenient use in the field.
A ping test or a file transfer between two workstations - connected to the
networking equipment - is useful and easy to implement for testing the
performance of the whole configuration.
Setup
Dip-switch
Set all the DIP switch toggles (other than 8 and 10 which are for SNMP
management and Fusion) to the OFF position for normal operation.
4 - TS5000/4U1
Compatibility
Peripheral equipment
Check the operating of the peripheral equipment connecting them through cables
(see Configuration 1 below).
Interfaces
Check the specifications compatibility (type, standard compliance) between the link
and the peripheral equipment interfaces.
Testing equipment
Chose an appropriate BER (Bit Error Rate) tester for checking the physical link
quality. A portable one is preferred for convenient use in the field.
Dip-switch Setup
Main Dip-Switch: Set all the DIP switch toggles (other than 8 and 10
which are for SNMP management and Fusion) to the OFF position
for normal operation.
Dip switch under the port in use: - switches 3&4 OFF for normal
operation.
- Line coding (AMI or HDB3) – Toggle 1.
- Receive Sensitivity (Short/Long Haul) – Toggle 2.
- Impedance (75 ohm/120 ohm) – Toggle 5.