Chapter 2 Installation and BIOS Setup
NI 8352/8353 User Manual 2-18 ni.com
used as a workstation. Select Server if your system is used as a server.
Select Disable to disable the fan speed control function and allow the
onboard fans to run constantly at full speed (12 V). Select 4-pin Quiet
(or Super Quiet) to lower the fan speed and noise. The options are Disable
(default), 3-pin (Server), 3-pin (Workstation), 4-pin (Server), and 4-pin
(Workstation),
Voltage Monitoring
The following items are monitored and displayed:
• Vcore: 1.25 V
• 1.5 V
• –12 V
•Vdimm
• +3.3 V
• +12 V
•5 Vsb
• 5 VDD
•P_VTT
• Vbat
IPMI
Access this submenu to change the following settings. (This option is
available only when an IPMI card is installed in the system.)
IPMI Specification Version
This item displays the current IPMI version.
Firmware Version
This item displays the current firmware version.
System Event Logging
Select Enabled to enable IPMI event logging. When this function is set to
Disabled, the system continues to log events received via system interface.
The options are Enabled (default) and Disabled.