Configuring Your Server 4-7
Security
To set passwords on the BIOS
Select [Security] - [Set Supervisor Password] and enter a password.
Supervisor password and User password can be set separately, and only User password
has a restriction to access to SETUP utility.
To enable/disable the POWER switch and DUMP switch
To disable
Select [Security] - [Power Switch Inhibit] - [Enabled].
To enable
Select [Security] - [Power Switch Inhibit] - [Disabled].
IMPORTANT: Enabling [Power Switch Inhibit] disables forced
shutdown (see Chapter 8) as well as power on/off using the POWER
switch.
To set the secure mode
Select [Security] - [Secure Mode] and set each item.
External Devices
To set up external devices
Select [Advanced] - [I/O Device Configuration] and set up each device.
Internal Devices
To set up internal PCI devices of the server
Select [Advanced] - [PCI Configuration] and set up each device.
To clear the hardware configuration data (after installing/removing internal devices)