NEC 140Rc-4 Server User Manual


 
4-8 Configuring Your Server
PCI Hot Plug
To install the PCI board with the PCI hot plug
Select [Advanced] - [PCI Configuration] - [Hot Plug PCI Control] -
[Minimum/Middle/Maximum*]
* The setting varies depending on the PCI board subject to the hot plug. See the table
below.
N code Board name Setting Value
N8104-85F 100BASE-TX Adapter Minimum
N8104-103F 1000BASE-T Adapter Minimum
Select [Advanced] - [PCI Configuration] - [Hot Plug PCI Control] - [Empty Bus Default
Speed] - [PCI Slots 5-6*]/[PCI Slots 7-8*] and set the frequency of the boards to be
installed.
* If the hot plugs are provided for PCI Slot 5-6 or PCI Slot 7-8, previously set the speeds
of the slots to meet those of the boards to be installed.
Saving the Configuration Data
To save the BIOS configuration data
Select [Exit] - [Exit Saving Changes] or [Save Changes].
To discard changes to the BIOS configuration data
Select [Exit] - [Exit Discarding Changes] or [Discard Changes].
To resume the default BIOS configuration data (may differ from factory-set value)
Select [Exit] - [Load Setup Defaults].
To save the current value as user default
Select [Exit] - [Save Custom Defaults].
To load the user-defined default
Select [Exit] - [Load Custom Defaults].