NEC 151944 Network Hardware User Manual


 
ND-46550 (E) CHAPTER 3
Page 45
Revision 2.0
2.2.6 Mounting of Line/Trunk Card on Small Platform PIM
Mount the Line/Trunk cards in the following slots on the Remote PIM. Connect the line cables referring to Figure
3-21 through Figure 3-23 and Table 3-8.
Figure 3-21 Mounting Location of Line/Trunk Card (Small Platform)
Table 3-8 LTC Connector Accommodation (Small Platform)
REMOTE PIM TYPE LTC CONNECTOR CARD SLOT NUMBER
Small Platform LTC0 LT00~LT02
LTC1 LT03~LT05
LTC2 LT06~LT07
LTC1
LTC0 LTC2
BWB
FRONT
P
W
R
Remote PIM
LT00
LT01
LT02
LT03
LT04
LT05
LT06
LT07
LT08
LT09
LT10
MP
LINE/TRUNK
Note 1: The CSI card can not be used on the Remote PIM.
Note 2: One port of the last 24 ports can not be used for line/trunk, because it is used for control
signaling channel.
CARD
*1
*2
*3
*1 When providing only one DAIB card (Max. 23 ports): LT00~LT02 slot
*2 When providing one DAIB card and one DAIC card (Max. 47 ports): LT00~LT05 slot