NEC 151944 Network Hardware User Manual


 
ND-46550 (E) CHAPTER 3
Page 51
Revision 2.0
2.2.8 Mounting of Line/Trunk Card on PIM N - UB (64 port PIM)
Mounting of Line/Trunk cards in the slots on the Remote PIM. Connect the line cables referring to Figure 3-27
through Figure 3-29 and Table 3-10.
Figure 3-27 Mounting Location of Line/Trunk Card
Table 3-10 LTC Connector Accommodation
REMOTE PIM TYPE LTC CONNECTOR CARD SLOT NUMBER
PIM N-UB
LTC0 LT00~LT05
LTC1 LT06~LT09, LT10, LT11
LTC2 LT12~LT15
LTC1
LTC0 LTC2
BWB
FRONT
P
W
R
Remote PIM
LT00
LT01
LT02
LT03
LT04
LT05
LT06
LT07
LT08
LT09
LT10
MP
LINE/TRUNK
CARD
LT11
LT12
LT13
LT14
LT15
*1
*2
*3
*1 When providing one DAIB card only (Max. 23 ports): LT00~LT05 slots
*2 When providing one DAIB card and one DAIC card (Max. 47 ports): LT00~LT11 slots
*3 When providing one DAIB card and two DAIC cards (Max. 64 ports): LT00~LT15 (DAIC in slot AP6 ~ AP8)
Note 1: The CSI card cannot be used on the Remote PIM.
Note 2: One port of the last 24 ports cannot be used for Line/Trunk, because it is used for