NEC 151944 Network Hardware User Manual


 
CHAPTER 4 ND-46550 (E)
Page 68
Revision 2.0
PN-DAIB (DAIB) RUN lamp is not flashing Abnormal operation of
DAIB card
Reset MB switch.
(DownUpDown)
If fault cannot be cleared,
replace card.
LINK lamp is not on Layer 2 link connection
failure between DAIA and
DAIB
Check whether cable between
DAIA and DAIB is correctly
connected. (Refer to Chapter 3,
Section 2.3.)
Reset MB switch
(DownUpDown)
RED lamp is on PCM signal loss or Frame
Alignment signal loss
Check whether cable between
DAIA and DAIB is correctly
connected. (Refer to Chapter 3,
Section 2.3.)
Reset MB switch of DAIA card
on main site.
(DownUpDown)
RMT lamp is on Remote alarm Check whether cable between
DAIA and DAIB (sending side)
is correctly connected. (Refer
to Chapter 3, Section 2.3.)
Table 4-1 Remedial Action on Each Lamp Status (Continued)
CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION