PN-DAIC (DAIC) RUN lamp is not flashing Abnormal operation of
DAIC card
Reset MB switch.
(DownUpDown)
If the fault can not be cleared,
replace card.
LINK lamp is not on Layer 2 link connection
failure between DAIA and
DAIB
Check whether cable between
DAIA and DAIB is correctly
connected. (Refer to
CHAPTER 3, Section 2.3.)
Reset MB switch
(DownUpDown)
Check whether cable between
DAIC cards is correctly
connected. (Refer to
CHAPTER 3, Section 2.3.)
RED lamp is on PCM signal loss or Frame
Alignment signal loss
Check whether cable between
DAIC cards is correctly
connected. (Refer to
CHAPTER 3, Section 2.3.)
RMT lamp is on Remote alarm Check whether cable between
DAIC cards (sending side) is
correctly connected. (Refer to
CHAPTER 3, Section 2.3.)
Table 4-1 Remedial Action on Each Lamp Status (Continued)