GS700TS Smart Switch Software Administration Manual
Monitoring the Switch 7-8
v1.0, June 2009
The Server Log screen contains the following fields:
• Server IP – Enter the server’s IP address to which logs can be sent.
• UDP Port – Enter the UDP port to which the server logs are sent. The possible range is 1
- 65535. The default value is 514.
• Facility – Select an application from which device logs are sent to the remote server. Only
one facility can be assigned to a single server. If a second facility level is assigned, the first
facility is overridden. All applications defined for a device utilize the same facility on a
server. The field default is Local 0. The possible field values are Local 0 - Local 7.
• Description – Enter a user-defined server description.
• Minimum Severity – Select the minimum severity level for which logs are sent to the
server. For example, if Notice is selected, all logs with a severity level of Notice and
higher are sent to the remote server. The default value is Informational. The possible field
values are:
– Emergency – Displays the highest warning level. If the system is down or not
functioning properly, an emergency log message is saved to the specified logging
location.
– Alert – Indicates the system needs immediate attention. Alert is the second highest
warning level. An alert log is saved, if there is a serious device malfunction; for
example, all device features are down.
– Critical – Indicates the system is in a critical state. Critical is the third highest warning
level. A critical log is saved if a critical device malfunction occurs; for example, two
device ports are not functioning, while the rest of the device ports remain functional.
– Error – Indicates a device error has occurred; for example, if a single port is offline.
– Warning – Displays the lowest level of a device warning. The device is functioning,
but an operational problem has occurred.
– Notice – Indicates the system is functioning properly, but a system notice is logged.
– Informational – Provides device information.
– Debug – Provides debugging messages.
2. Select the server entry.
3. Enter the Server IP address in the provided field in the first row.
4. Enter the UDP Port number in the provided field in the first row.
5. Select the Facility assigned to the server from the list in the provided field in the first row.