Nortel Networks 42C4911 Switch User Manual


 
Alteon OS Application Guide
38
Chapter 1: Accessing the Switch 42C4911, January 2007
3. Assign the user to the user group. Use the group table to link the user to a particular
access group.
If you want to allow user access only to certain MIBs, see the 'View based Configuration' sec-
tion.
View based Configurations
CLI User equivalent
To configure an SNMP user equivalent to the CLI 'user,' use the following configuration:
>> # /cfg/sys/ssnmp/snmpv3/group 5
>> SNMPv3 vacmSecurityToGroup 5# uname admin
>> SNMPv3 vacmSecurityToGroup 5# gname admingrp
/c/sys/ssnmp/snmpv3/usm 4 (Configure the user)
name "usr"
/c/sys/ssnmp/snmpv3/access 3 (Configure access group 3)
name "usrgrp"
rview "usr"
wview "usr"
nview "usr"
/c/sys/ssnmp/snmpv3/group 4 (Assign user to access group 3)
uname usr
gname usrgrp
/c/sys/ssnmp/snmpv3/view 6 (Create views for user)
name "usr"
tree "1.3.6.1.4.1.1872.2.5.1.2" (Agent statistics)
/c/sys/ssnmp/snmpv3/view 7
name "usr"
tree "1.3.6.1.4.1.1872.2.5.1.3" (Agent information)
/c/sys/ssnmp/snmpv3/view 8
name "usr"
tree "1.3.6.1.4.1.1872.2.5.2.2" (L2 statistics)
/c/sys/ssnmp/snmpv3/view 9
name "usr"
tree "1.3.6.1.4.1.1872.2.5.2.3" (L2 information)
/c/sys/ssnmp/snmpv3/view 10
name "usr"
tree "1.3.6.1.4.1.1872.2.5.3.2" (L3 statistics)
/c/sys/ssnmp/snmpv3/view 11
name "usr"
tree "1.3.6.1.4.1.1872.2.5.3.3" (L3 information)