Nortel Networks 42C4911 Switch User Manual


 
Alteon OS Application Guide
78
Chapter 3: VLANs 42C4911, January 2007
Viewing and Configuring PVIDs
Use the following CLI commands to view PVIDs:
Port information:
NOTEThe sample screens that appear in this document might differ slightly from the screens
displayed by your system. Screen content varies based on the type of BladeCenter unit that you
are using and the firmware versions and options that are installed.
Port Configuration:
Alias Port Tag Fast PVID NAME VLAN(s)
----- ---- --- ---- ---- -------------- ----------------------------
---
INT1 1 n n 1 INT1 1
INT2 2 n n 1 INT2 1
INT3 3 n n 1 INT3 1
INT4 4 n n 1 INT4 1
INT5 5 n n 1 INT5 1
INT6 6 n n 1 INT6 1
INT7 7 n n 1 INT7 1
INT8 8 n n 1 INT8 1
INT9 9 n n 1 INT9 1
INT10 10 n n 1 INT10 1
INT11 11 n n 1 INT11 1
INT12 12 n n 1 INT12 1
INT13 13 n n 1 INT13 1
INT14 14 n n 1 INT14 1
MGT1 15 n n 4095 MGT1 4095
MGT2 16 n n 4095 MGT2 4095
EXT1 17 n n 1 EXT1 1
EXT2 18 n n 1 EXT2 1
EXT3 19 n n 1 EXT3 1
EXT4 20 n n 1 EXT4 1
EXT5 21 n n 1 EXT5 1
EXT6 22 n n 1 EXT6 1
EXT7 23 n n 4094 EXT7 4094
* = PVID is tagged.
>> /cfg/port INT7/pvid 7
Current port VLAN ID: 1
New pending port VLAN ID: 7
>> Port INT7#