Nortel Networks Contivity1510D Switch User Manual


 
Chapter 2 CLI Command Summary 91
Reference for the Contivity VPN Switch Command Line Interface
reload
This command forces the switch to reboot immediately. Options can be specified
to determine whether the switch turns off or reboots, which configuration to use
after a reboot, and other settings.
The user is prompted to confirm that they want to continue with the reload. If they
say yes and if the reload command is valid, the system reload commences in
approximately 10 seconds.
The Safe and Normal boot modes are used for secure management of the switch.
In Normal mode, the switch operates normally. In Safe mode, the HTTP, or FTP
traffic is allowed. No other VPN traffic is allowed through the secure management
tunnel or the switch.
Syntax
reload [power-off|restart] [boot-safe|boot-normal] [boot-drive {ide0|ide1}]
[config-file {latest|factory|config-name}] [disable-logins] [disable-after-restart]
[text]
Parameters
power-off If present, the switch powers down after it has completed
shutdown.
restart If present, the switch restarts after it has completed shutdown.
boot-safe If present, switch restarts in safe boot mode.
boot-normal If present, switch restarts in normal boot mode.
boot-drive Specify the drive from which the switch will reboot.
ide0|ide1 Disk drive from which bootable image will be loaded.
config-file Specify which configuration should be used after a reboot.