180 ISL installation
DCHI switch settings
For ISL functions, use the following switch settings for the J2 port:
RS-232 for 19.2 Kbps and below
HS (RS-422) for speeds above 19.2 Kbps
External clock (in LD 17) provided by modem, ADM, or ASIM, otherwise
DCHI will be running at 64 Kbps
DTE device configuration
Figure 67 "NT6D11AB, NT6D11AD DCHI with ISL high-speed programming
jumper settings" (page 180) shows the ISL high-speed programming jumper
settings for the NT6D11AB, NT6D11AE DCHI, and Figure 68 "NT6D11AB,
NT6D11AD DCHI with ISL low-speed programming jumper settings"
(page 181) shows the ISL low-speed programming jumper settings for the
NT6D11AB, NT6D11AE/AF DCHI.
Figure 67
NT6D11AB, NT6D11AD DCHI with ISL high-speed programming jumper settings
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007