Nortel Networks NN43001-301 Server User Manual


 
Replace the MSDL 99
8
Connect the appropriate cable between the NT6D80 and the PRI
card MSDL interface.
9
Enable the MSDL card in LD 96.
10
Unplug the MSDL card and reinsert it. If the red LED still does
not flash three times, leave the card installed for approximately 10
minutes to allow the card to be initialized.
11
After 10 minutes unplug the card and reinsert it. If the red LED does
not flash three times, the card is defective and must be replaced.
—End—
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
Copyright © 2003-2007, Nortel Networks
.