140 Configuring and managing ports and VLANs
NN47250-500 (Version 03.01)
System Contact:
System IP: 0.0.0.0
System idle timeout:3600
System MAC: 00:0B:0E:00:04:0C
===============================================================================
Boot Time: 2000-03-18 22:59:19
Uptime: 0 days 00:13:45
===============================================================================
Fan status: fan1 OK fan2 OK fan3 OK
Temperature: temp1 ok temp2 ok temp3 ok
PSU Status: Lower Power Supply DC ok AC ok Upper Power Supply missing
Memory: 156.08/496.04 (31%)
Total Power Over Ethernet : 0.000
===============================================================================
3 Configure ports 2 through 16 for connection to AP model 2330 and verify the configuration changes.
Type the following commands:
WSS# set port type ap 2-16 model 2330 poe enable
This may affect the power applied on the configured ports. Would you like to continue? (y/n) [n]y
success: change accepted.