Status Code Display Indications
Warning Indicators
This LCD Projector has a STATUS CODE Display which calls your attention to problem conditions existing inside
the LCD Projector. The LCD Projector displays a Status Code Indication each time an internal problem is detected.
If any of the following indications appear in the STATUS CODE Display, immediately turn off the Main Power
switch, and then see the chart to determine a course of action.
<LCD Projector>
STATUS CODE
Display
Symptom
STATUS
CODE
F-L
Problem
Possible Solution
Cooling fan malfunction.
Take the Projector to your nearest
Service Center.
F-0
A-n
A-0
A-1
Lamp Unit automatically
turns off due to abnormally
high internal temperature.
(Stand-by condition)
Misinstalled Air Filter Unit.
Properly install Air Filter Unit (See
page 43).
Temperature Sensor
malfunction.
Take the Projector to your nearest
Service Center.
Clogged air filter.
Blocked air intake.
The surrounding temperature
of the place of use may be
too high.
Clean the filter (See page 43).
Relocate projector to a proper
location.
Place Projector so that surrounding
temperature is between 5°C (41°F)
and 40°C (104°F) and the humidity is
between 10% and 80% (with no
condensation).
L-n
P-2
P-3
P-4
L-1
Lamp does not light up.
Take the Projector to your nearest
Service Center.
Abnormally high internal
temperature.
Lamp operation time is over
1000 hours.
Replace the Lamp unit. (See pages
44,45).
L-0
C-d
Lamp operation time is over
1100 hours.
1 Lamp is burned-out.
Lamp Voltage is not correct.
Abnormal temperature rise.
Other causes.
It is nearly time to replace
the Lamp Unit.
The Lamp Unit must be
replaced.
Forced cooling fan
operating to expedite lamp
replacement (See page 45).
Note:
Please wait one minute before turning the power back on, to allow the lamp to cool. A much longer time may be
required if the projector had attained an abnormally high internal temperature.
41